Sieves & Analysis Sieves

Sieves & Analysis Sieves

For the quality control of powders or granules, the knowledge and strict monitoring of the particle size distribution is an important component: The particle size distribution has a direct influence on the physical and chemical properties of solids and a constant product quality can only be guaranteed with the same grain distribution. Our range of analytical sieves and sieving machines, e.g. from Haver & Boecker, fulfills the increasing demands on grain size analysis and enables easy, fast, reproducible and precise analyzes.

Further information on test sieves and test sieve shakers is provided here

10 Items

Product Image of support sieve, POLYSULFON, spare part for 42 03, 4204
support sieve, POLYSULFON, spare part for 42 03, 4204
Item number: PA87265
Brand: Pall Corporation
$14.83
Product Image of Outlet strainer stainless steel type 316 spare part, 1/PAK
Outlet strainer stainless steel type 316 spare part, 1/PAK
Item number: PA72994
Brand: Pall Corporation
$316.80
Product Image of Support screen, type 316 stainless steel, 1pc/PAK
Support screen, type 316 stainless steel, 1pc/PAK
Item number: PA72978
Brand: Pall Corporation
$584.40
Product Image of Outlet strainer stainless steel type 316 Spare part, 1/PAK
Outlet strainer stainless steel type 316 Spare part, 1/PAK
Item number: PA72191
Brand: Pall Corporation
$972.00
Product Image of Support sieve stainless steel type 316 spare part F, 1pc/PAK
Support sieve stainless steel type 316 spare part F, 1pc/PAK
Item number: PA72161
Brand: Pall Corporation
$2,052.00
Product Image of support sieve, POLYSULFON, spare part for 41 21, 1119
support sieve, POLYSULFON, spare part for 41 21, 1119
Item number: PA87264
Brand: Pall Corporation
$11.17
Product Image of support sieve stainless steel TYP 316 spare part F
support sieve stainless steel TYP 316 spare part F
Item number: PA81312
Brand: Pall Corporation
$50.08
Product Image of support sieve stainless steel TYP 316 spare part F
support sieve stainless steel TYP 316 spare part F
Item number: PA79791
Brand: Pall Corporation
$100.57
Product Image of Stützsieb Edelstahl Ersatzteil for 1235, 1/PAK
Stützsieb Edelstahl Ersatzteil for 1235, 1/PAK
Item number: PA72970
Brand: Pall Corporation
$73.68
Product Image of Support sieve, stainless steel, 47 MM spare part for 1220, 4230, 4238
Support sieve, stainless steel, 47 MM spare part for 1220, 4230, 4238
Item number: PA4235
Brand: Pall Corporation
$362.40

10 Items

Test sieves are used for reliable and reproducible results in the context of quality assurance. Retsch test sieves correspond to the standards ISO 3310 or ASTM E11. Prior to delivery, each sieve is optically measured and granted a test report. Due to extensive optical inspection Retsch offers excellent product quality as well as many more advantages:

  • One-piece sieve frame and fabric-transition without grooves prevent cross contamination, sample residues etc.
  • No hollow spaces which need to be sealed (no epoxy)
  • High degree of corrosion resistance and easy to clean thanks to high-alloy stainless steels
  • Permanently tight sieve fabric due to innovative tensioning technology
  • Maximum stability and optimum sealing when used in sieve stacks thanks to the o-ring which is placed in the recess designed for this purpose
  • Individualized laser engraving enables clear and precise labeling of the sieves with full traceability

Cleaning and Maintenance of Test Sieves

Test sieves are analytical instruments and should be treated with care. Before test sieves are used for the first time, they ideally should be rinsed with ethanol or isopropanol to remove any preservative residues. After the sieving process the sieving fractions are removed from the sieves. By gently tapping the inverted sieve frame on bench surfaces, dry sieve gauze can be removed. If necessary, brush the bottom of the gauze gently with a fine hair brush. Test sieves with a mesh size < 500 µm should be cleaned in ultrasonic cleaning baths for 2-3 minutes and can be dried by placing the test sieves vertically in laboratory ovens at <80°C. During the sieving process, the samples should not be forced through the wire gauze to maintain the high quality of sieve body and gauze. When not in use, test sieves should be stored in a dry and dust-free location.

Test Sieve Shakers by Retsch

Test sieve shakers produce exact and reproducible results and comply with the requirements for the test materials monitoring according to DIN EN ISO 9000 ff. Sieving machines by Retsch cover a wide measuring range. Thanks to various sieving motions and sieve sizes it is possible to select the ideal instrument for practically any bulk material.

  Measuring range  Sieving motion Amplitude Time display Suitable sieve diameters
Vibratory Sieve Shaker AS 200 basic  20 µm - 25 mm throwing motion with angular momentum analog, 0 - 3 mm analog, 1 - 60 min 100 mm / 150 mm / 200 mm / 203 mm (8")
Vibratory Sieve Shaker AS 200 digit 20 µm - 25 mm throwing motion with angular momentum analog, 0 - 3 mm digital, 1 - 99 min 100 mm / 150 mm / 200 mm / 203 mm (8")
Vibratory Sieve Shaker AS 200 control 20 µm - 25 mm throwing motion with angular momentum digital, 0,2 - 3 mm digital, 1 - 99 min 100 mm / 150 mm / 200 mm / 203 mm (8")
Vibratory Sieve Shaker AS 300 control 20 µm - 40 mm throwing motion with angular momentum 0,2 - > 2 mm digital, 1 - 99 min 100 mm / 150 mm / 200 mm / 203 mm (8") / 305 mm / 315 mm
Vibrationssiebmaschine AS 450 basic 25 µm - 125 mm throwing motion with angular momentum - 3D movement digital, 0 - > 2 mm   400 mm / 450 mm
Vibrationssiebmaschine AS 450 control 25 µm - 125 mm throwing motion with angular momentum - 3D movement digital, 0 - > 2,2 mm   400 mm / 450 mm
Air Jet Sieving Machine AS 200 jet 10 µm - ~ 4 mm dispersion by air jets Speed: digital, 5 - 55 min-1 (Düse)    
Horizontal Sieve Shaker AS 400 control 45 µm - 63 mm horizontal circular motion     100 mm / 150 mm / 200 mm / 203 mm (8") / 305 mm / 315 mm / 400 mm
Tap Sieve Shaker AS 200 tap 20 µm - 25 mm horizontal circular motion with taps     200 mm / 203 mm (8")

EasySieve, the software for particle size analyses is able to automatically control and document the necessary measurement and weighing procedures. All available parameters such as sieve stack configuration, dead weight of the sieve, sieve shaker settings as well as the characteristics, which may have to be calculated, can be entered. The program accepts automatic and manual data entries from both scale and sieve system. The sieve shakers of the series “control” can be automatically controlled with EasySieve. The loaded sieves are reweighed after the sieve analysis. By determining the weight difference, the program automatically detects the mass proportions. The EasySieve software calculates particle distributions, the characteristic values of the particle size, cumulative throughput or residual values and distribution density and presents the results in tables or charts.

Test sieve shakers by HAVER

With test sieve shakers by Haver&Boecker sieve analysis of up to 3kg sample weight is convenient and precise. HAVER EML 200 digital plus for test sieves with diameters of up to 203 mm can be used for dry and wet sieving of 3 kg bulk material maximum. You can set and store sieving time, interval and amplitude for reproducible sieving results. The 3D laboratory sieve shaker saves time and manual re-sieving. The self-readjusting amplitude enables comparable sieving results. Test sieves can be changed easily by using the quick-release clamping system TwinNut. Further, memory of 99 sieving programs, low-noise and maintenance free operating are advantages of HAVER test sieve shakers.

The HAVER CSA 5.0 software enables precise and easy PC-aided analysis of standard sieve systems. The results of measurements are documented for quality control and can be introduced into statistics and reports due to the complex data processing. Three versions of this software are available which differ in the scale of functions.

The test sieve shakers (BASIC and EXPERT) enable:

  • Input of sieve sets, customers and materials / evaluation of analysis with protocol and particle size account
  • Account of AFS-numbers
  • Graphics, e.g. cumulative oversize distribution curve

Further, HAVER CSA 5.0 EXPERT offers:

  • Statistic functions
  • Expanded account, e.g. sauter mean diameter
  • Definition of particle limits / loading of comparable data
  • Data bank functions
  • Data export
  • Import of aged data

Go back to products