Electrodes

pH Electrodes for the laboratory

We offer pH electrodes or combination electrodes for pH measuring devices from Agilent Technologies, Mettler Toledo and WTW. The electrodes can be used in a wide range of applications such as pH measurements in food testing. The chemical composition, homogeneity, temperature, process pressure and the pH range of the sample are important criteria when choosing the right electrode. Contact our customer service to assist you on selecting the right electrode.

A pH electrode selection guide can be found here.

Items 1-50 of 839

Product Image of Conductivity electrode TetraCon 325
Conductivity electrode TetraCon 325
Item number: WW301960
Brand: WTW

In stock

$703.75 $725.00
Product Image of WP 90/3 3 exchange membrane heads
WP 90/3 3 exchange membrane heads
Item number: WW202725
Brand: WTW

In stock

$220.00 $226.25
Product Image of pH-Combination electrode Sensolyt
pH-Combination electrode Sensolyt
Item number: WW109115
Brand: WTW

In stock

$381.25 $392.50
Product Image of pH combination electrode InLab Micro
pH combination electrode InLab Micro
Item number: MR51343160
Brand: Mettler-Toledo

In stock

$506.24
Product Image of pH combination electrode InLab Routine Expert Pro
pH combination electrode InLab Routine Expert Pro
Item number: MR51343101
Brand: Mettler-Toledo

In stock

$454.14
Product Image of pH combination electrode InLab Routine Pt1000
pH combination electrode InLab Routine Pt1000
Item number: MR51343056
Brand: Mettler-Toledo

In stock

$446.13
Product Image of LE409 pH electrode made of glass with liquid electrolyte for simple and fast measurements in the laboratory, electrolyte refillable
LE409 pH electrode made of glass with liquid electrolyte for simple and fast measurements in the laboratory, electrolyte refillable
Item number: MR51340331
Brand: Mettler-Toledo

In stock

$177.65
Product Image of pH electrode LE438 (plastic, 3-in-1)
pH electrode LE438 (plastic, 3-in-1)
Item number: MR51340242
Brand: Mettler-Toledo

In stock

$284.51
Product Image of pH-Electrode for Titration in non-aqueous Media, Type N 6480 Eth
pH-Electrode for Titration in non-aqueous Media, Type N 6480 Eth
Item number: SI285092329
Brand: SI Analytics

In stock

$426.25
Product Image of pH-Combination Electrode with Sensor Detection, Type A 162 2M-DIN-ID
pH-Combination Electrode with Sensor Detection, Type A 162 2M-DIN-ID
Item number: SI285130275
Brand: SI Analytics
$516.25
Product Image of SenTix® ORP-T 900 ORP electrode, digital
SenTix® ORP-T 900 ORP electrode, digital
Item number: WW103791
Brand: WTW

In stock

$370.00
Product Image of SenTix 940 combined pH sensor, digital
SenTix 940 combined pH sensor, digital
Item number: WW103740
Brand: WTW

In stock

$356.25
Product Image of SenTix Mic-D combined pH-electrode
SenTix Mic-D combined pH-electrode
Item number: WW103660
Brand: WTW

In stock

$472.50
Product Image of SenTix ORP ORP combination electrode
SenTix ORP ORP combination electrode
Item number: WW103648
Brand: WTW

In stock

$325.00
Product Image of SenTix H precision pH combination electrode
SenTix H precision pH combination electrode
Item number: WW103644
Brand: WTW
$373.75
Product Image of SenTix 81 standard pH combination electrode with built-in temperature sens
SenTix 81 standard pH combination electrode with built-in temperature sens
Item number: WW103642
Brand: WTW

In stock

$363.75
Product Image of SenTix 61 standard pH combination electrode
SenTix 61 standard pH combination electrode
Item number: WW103640
Brand: WTW

In stock

$238.75
Product Image of SenTix 21 basic pH combination electrode
SenTix 21 basic pH combination electrode
Item number: WW103631
Brand: WTW

In stock

$205.00
Product Image of Connectors-Cable-Combination L1A
Connectors-Cable-Combination L1A
Item number: SI285122456
Brand: SI Analytics

In stock

$82.45
Product Image of pH-combination electrode Typ 405DXKS8/225
pH-combination electrode Typ 405DXKS8/225
Item number: WW109234
Brand: WTW
$442.50 $456.25
Product Image of A 325/K Plastic armoring
A 325/K Plastic armoring
Item number: WW903830
Brand: WTW
$343.75 $353.75
Product Image of TetraCon 325-10 Conductivity cell with built-in temperature sensor
TetraCon 325-10 Conductivity cell with built-in temperature sensor
Item number: WW301972
Brand: WTW
$857.50 $917.50
Product Image of TetraCon 325-3 Conductivity cell with built-in temperature sensor
TetraCon 325-3 Conductivity cell with built-in temperature sensor
Item number: WW301970
Brand: WTW
$750.00 $772.50
Product Image of LR 325/001 Trace conductivity cell with built-in temperature sensor
LR 325/001 Trace conductivity cell with built-in temperature sensor
Item number: WW301962
Brand: WTW
$1,457.50 $1,501.25
Product Image of LR 325/01 ultrapure water LR 325/01 ultrapure water
LR 325/01 ultrapure water LR 325/01 ultrapure water
Item number: WW301961
Brand: WTW
$872.50 $898.75
Product Image of TetraCon® 925/C
TetraCon® 925/C
Item number: WW301721
Brand: WTW
$1,086.25 $1,118.75
Product Image of TetraCon® 925/LV-P
TetraCon® 925/LV-P
Item number: WW301719
Brand: WTW
$971.25 $1,000.00
Product Image of TetraCon® 925/LV
TetraCon® 925/LV
Item number: WW301718
Brand: WTW
$945.00 $973.75
Product Image of TetraCon 325 S Conductivity cell with built-in temperature sensor
TetraCon 325 S Conductivity cell with built-in temperature sensor
Item number: WW301602
Brand: WTW
$892.50 $918.75
Product Image of WP3-D Membrane heads
WP3-D Membrane heads
Item number: WW202740
Brand: WTW
$222.50 $228.75
Product Image of WP3-ST 3 exchange membrane heads
WP3-ST 3 exchange membrane heads
Item number: WW202738
Brand: WTW
$231.25 $238.75
Product Image of Low-maintenance pH-combination electrode with Pt 100
Low-maintenance pH-combination electrode with Pt 100
Item number: WW109239
Brand: WTW
$533.75 $550.00
Product Image of Low-maintenance pH-combination electrode
Low-maintenance pH-combination electrode
Item number: WW109233
Brand: WTW
$385.00 $396.25
Product Image of Rdox-combination electrode
Rdox-combination electrode
Item number: WW109125EX
Brand: WTW
$600.00 $617.50
Product Image of pH-combination electrode for potentially explosive area & Drinking water applications
pH-combination electrode for potentially explosive area & Drinking water applications
Item number: WW109119EX
Brand: WTW
$451.25 $465.00
Product Image of pH-combination electrode, specially for Drinking water applications
pH-combination electrode, specially for Drinking water applications
Item number: WW109119
Brand: WTW
$376.25 $387.50
Product Image of pH-combination electrode for potentially explosive area
pH-combination electrode for potentially explosive area
Item number: WW109118EX
Brand: WTW
$650.00 $670.00
Product Image of pH-combination electrode, measuring range 4 … 12 pH
pH-combination electrode, measuring range 4 … 12 pH
Item number: WW109118
Brand: WTW
$538.75 $555.00
Product Image of pH-combination electrode for potentially explosive area, normal polluted wastewater
pH-combination electrode for potentially explosive area, normal polluted wastewater
Item number: WW109117EX
Brand: WTW
$345.00 $355.00
Product Image of pH-Combination electrode Sensolyt
pH-Combination electrode Sensolyt
Item number: WW109117
Brand: WTW
$290.00 $298.75
Product Image of pH-combination electrode for potentially explosive area, heavily polluted wastewater
pH-combination electrode for potentially explosive area, heavily polluted wastewater
Item number: WW109115EX
Brand: WTW
$511.25 $526.25
Product Image of pH-combination electrode for Drinking water applications, measuring range 0 … 14 pH
pH-combination electrode for Drinking water applications, measuring range 0 … 14 pH
Item number: WW109103
Brand: WTW
$350.00 $360.00
Product Image of pH-combination electrode for normal polluted wastewater, measuring range 0 … 12 pH
pH-combination electrode for normal polluted wastewater, measuring range 0 … 12 pH
Item number: WW109102
Brand: WTW
$280.00 $288.75
Product Image of Protection cage for ISE electrodes
Protection cage for ISE electrodes
Item number: WW107056
Brand: WTW
$226.61 $233.04
Product Image of pH combination electrode with 1 m fixed cable A 7780 NTC30 DIN N
pH combination electrode with 1 m fixed cable A 7780 NTC30 DIN N
Item number: SI285101290
Brand: SI Analytics

In stock

$416.25
Product Image of SenTix® Top 46, plastic pH electrode, PEEK shaft, polymer electrolyte, hole diaphragm, temperature sensor, BNC plug and RCA plug
SenTix® Top 46, plastic pH electrode, PEEK shaft, polymer electrolyte, hole diaphragm, temperature sensor, BNC plug and RCA plug
Item number: WW103817
Brand: WTW
$353.75 $363.75
Product Image of SenTix® Top 41, plastic pH electrode, PEEK shaft, polymer electrolyte, hole diaphragm, temperature sensor, waterproof DIN plug
SenTix® Top 41, plastic pH electrode, PEEK shaft, polymer electrolyte, hole diaphragm, temperature sensor, waterproof DIN plug
Item number: WW103816
Brand: WTW
$353.75 $363.75
Product Image of SenTix® Rx, redox electrode with plastic shaft and gel electrolyte, (platinum silver/silver chloride), with plug head, length 120 mm
SenTix® Rx, redox electrode with plastic shaft and gel electrolyte, (platinum silver/silver chloride), with plug head, length 120 mm
Item number: WW103815
Brand: WTW
$258.75 $266.25
Product Image of SenTix® 87, glass pH electrode, liquid electrolyte, temperature sensor NTC 10 kOhm, BNC connector and 2 mm pin connector, for Sartorius devices
SenTix® 87, glass pH electrode, liquid electrolyte, temperature sensor NTC 10 kOhm, BNC connector and 2 mm pin connector, for Sartorius devices
Item number: WW103814
Brand: WTW
$358.75 $370.00
Product Image of SenTix® 86, glass pH electrode, liquid electrolyte, temperature sensor, BNC plug and RCA plug, for Frem systems
SenTix® 86, glass pH electrode, liquid electrolyte, temperature sensor, BNC plug and RCA plug, for Frem systems
Item number: WW103813
Brand: WTW
$358.75 $370.00

What is required for pH measurements?

A special measuring tool for hydronium ions which the pH value refers to, is required to measure the pH value. The principle of the measurement is based on a sensor with a glass membrane, which selectively detects hydronium ions and registers the reaction between the membrane and a sample solution. This glass electrode potential alone does not provide sufficient information, a second sensor is thus required which provides the reference potential for the pH sensor. To determine the pH value of the solution, the potential difference between these electrodes must be measured.

The reaction of the pH-sensitive glass electrode depends on the concentration of the H+ ions (or H3O+). Hence, pH is a measurement of both acidity and alkalinity, a selective measurement of hydronium ion activity. On the other hand, the reference electrode does not react to the concentration of the H+ ions in the sample solution and always delivers the same constant potential which is used to measure the potential of the pH sensor. The difference in potential between the two electrodes determines the pH of the solution. Since this potential is a linear function of the hydronium ion concentration in the solution, the concentration can be measured quantitatively.

Nowadays, the pH sensor and the reference sensor are very often housed in one electrode. This combination of reference and pH electrode is called a combined pH electrode. Each of these three types of electrodes is different and has its own characteristics and properties.

pH electrodes

The pH electrode is the component that actually registers the pH of the solution. It consists of a glass shaft with a thin glass membrane at the lower end that is H+ ion sensitive. When this membrane comes into contact with an aqueous solution, the outside of the membrane glass forms a gel layer. A similar gel layer is also formed on the inside of the membrane glass as the electrode is filled with an internal aqueous electrolyte solution.

The H+ ions in and around the gel layer can - depending on the pH value and thus the H+ ion concentration of the measurement solution - either diffuse into or out of the layer. If the solution is alkaline, the H+ ions diffuse out of the layer and a negative charge is created on the outside of the membrane. Since the glass electrode has an internal buffer with a constant pH value, the potential on the inner surface of the membrane remains constant during the measurement. The potential of the pH electrode is therefore the difference between the inner and the outer charge of the membrane.

Reference electrodes

The task of the reference electrode is to provide a defined stable reference potential against which the potential of the pH sensor can be measured. To achieve this, the reference electrode must be made of glass, which is not sensitive to the H+ ions in the solution. It must also be open to the sample environment in which it is immersed. An opening or a diaphragm is made in the shaft of the reference electrode through which the inner solution or the reference electrolyte can flow into the sample. To obtain correct measurements, the reference electrode and the pH half-cell must be in the same solution.

The electrode construction consists of an inner reference element that is immersed in a defined reference buffer solution and has indirect contact with the sample solution via the diaphragm. This contact chain ensures a stable potential. There are several reference systems available, but the silver/silver chloride system is now used almost exclusively in laboratories. The potential of this reference system is defined by the reference electrolyte and the silver/silver chloride reference element. It is important for the reference electrolyte to have a high ion concentration and a low electrical resistance.

As the reference electrolyte flows into the sample during the measurement, pay attention to possible reactions between the reference electrolyte and the sample solution. Such reactions could affect the electrode and measurement.

Combined electrodes

Combined electrodes are much easier to handle than two separate electrodes and are therefore used very frequently today. In the combined electrode, the pH-sensitive glass electrode is surrounded concentrically by the reference electrode, which is filled with the reference electrolyte. The pH and reference components of the combined electrode have the same properties as the corresponding separate electrodes. The only difference is that they are integrated in a single electrode for easier handling. The use of individual pH and reference electrodes instead of a single combined electrode is only recommended if the two components of the combined electrode have a very different expected life span.

To further simplify pH measurements, a temperature sensor can be used together with the pH and the reference element in the same shaft. This enables temperature compensation while measurung pH. Such electrodes are also referred to as 3-in-1 electrodes.

pH and redox electrodes for every application

Electrodes may consist of different materials (very common are platinum, calomel or hydrogene electrodes) and are hence very versatile. They are knowned as single-rod measuring cells which are used to determine the pH value. However, the standard hydrogene electrode serves here as the reference electrode to determine the standard potential of redox couples. The most common ones are solid state electrodes containing of a metal and its dilution. Liquid electrodes such as quicksilver electrodes can also be used. 

Click here to return to products.