HPLC Column Raptor C18, 90Å, 1.8 µm, 100 x 3.0 mm

HPLC Column Raptor C18, 90Å, 1.8 µm, 100 x 3.0 mm

Item number: RE930421E
Brand: Restek
PAK (1 pc)

Description

Restek chemists were the first to combine the speed of surface porous particles (also known as SPP or "core-shell" particles) with the resolution of highly selective USLC technology. With this new generation of chromatographic columns, you can achieve better peak separations and shorter analysis times with existing HPLC and UHPLC instruments.

When you need a general-purpose LC column, don't just pick any C18. Opt for the speed, efficiency, and durable ruggedness of the Raptor C18. This traditional endcapped C18 phase offers the highest hydrophobic retention of any Raptor phase and is compatible with a wide range of mobile phases from moderately acidic to neutral (pH 2-8). Whether for food safety, environmental or bioanalytical analysis, this phase provides consistently excellent data quality in less time for a variety of reversed-phase applications, matrices and compound classes. To reduce costs and increase profitability, columns must last longer, data must be reproducible, and existing HPLC and UHPLC instruments must run faster. Achieve your goal with the only general-purpose C18 column that gives you accelerated selectivity.

Stationary phase category: C18, octadecylsilane (L1)
Ligand type: C18 with endcapping
Particle size: 1.8 µm, 2.7 µm, or 5 µm surface porous silica (SPP or "core-shell")
pore size: 90 Å
Carbon loading: 9 % (1.8 µm), 7 % (2.7 μm), 5 % (5 μm)
Endcapping: yes
Surface area: 125 m2/g (1.8 µm), 130 m2/g (2.7 µm), or 100 m2/g (5 µm)
Recommended use:
pH range: 2.0-8.0
Maximum temperature: 80 °C
Maximum pressure: 1034 bar/15000 psi* (1.8 μm), 600 bar/8700 psi (2.7 μm); 400 bar/5800 psi (5 μm)

* For maximum life, the recommended maximum pressure for 1.8 μm sized particles is 830 bar/12000 psi.

Features:

Compatible with moderately acidic to neutral mobile phases (pH 2-8).
Excellent data quality for food, environmental, bioanalytical and other applications.

Switch to a C18 column:

When you need a general-purpose column for reversed-phase chromatography.
When you need to increase the retention of hydrophobic compounds.

Note: We strongly recommend that you only order a semi-preparative or preparative column once you have evaluated the desired separation on an equivalent column on an analytical scale.
Because we cannot reuse a column or the silica within it once it leaves our facility, we cannot accept returns of large columns.

More Information

  • Additional
Brand Restek
Carbon load 18.0%
Column description Raptor
Package specification C18 (RP18, ODS, Octadecyl)
Endcapping yes
Inner diameter 3 mm
mode Reversed Phase (RP)
Particle Size 1,8 µm
pH Range 2 - 8
Pore size 90 Å
USP number L1
Length 100 mm

You might also be interested in the following products

  1. Product Image of Column Storage Cabinet, 30 columns (up to 300mm length)
    Column Storage Cabinet, 30 columns (up to 300mm length)
    Item number: AAColStore30
    Brand: Altmann Analytik

    In stock | 20 Units

    $482.07 $535.63
  2. Product Image of Crimper for 8 mm crimp caps
    Crimper for 8 mm crimp caps
    Item number: AAV19171116
    Brand: Altmann Analytik

    In stock | 1 Units

    $306.72
  3. Product Image of Water for chromatography LiChrosolv, 2,5 L, orderable only in packs of 4
    Water for chromatography LiChrosolv, 2,5 L, orderable only in packs of 4
    Item number: MC1153332500
    Brand: Merck

    In stock | 64 Units

    $119.00